ELECTRONIC SPACE PRODUCTS INTERNATIONAL
1050 Benson Way, Ashland, OR 97520
Toll Free (800) 638-2581 * Fax (541) 488-8313
E-Mail: sales@espimetals.com
MATERIAL SAFETY DATA SHEET
I PRODUCT IDENTIFICATION
Trade Name: Ammonium Hexabromoosmate IV Formula: (NH4)2OsBr6
II HAZARDOUS INGREDIENTS
%: 100 TLV(Units): 1.0 mg/m3
III PHYSICAL DATA
Melting Point: N/A Specific Gravity: N/A
Appearance and Odor: Black/brown crystalline powder. Solubility in Water: Very soluble
IV FIRE AND EXPLOSION HAZARDS DATA
Flash Point: N/A Flammable Limits: Not flammable
Extinguishing Media: CO2, Foam, dry chemical.
Special Firefighting Procedures: Self-contained breathing apparatus.
Unusual Fire and Explosion Hazards: May emit toxic fumes upon decomposition.
V HEALTH HAZARD INFORMATION
Effects of Over Exposure: Mucus membrane irritant, corrosive solid may cause chemical burns to skin.
EMERGENCY AND FIRST AID PROCEDURES: Remove patient from area of exposure to fresh air.
EXTERNAL: Flush with soap and water for 15 minutes.
EYES: Flush with eye bath.
INTERNAL: Contact poison control center/physician.
VI REACTIVITY DATA
Stability: Stable
Conditions to Avoid: Extreme heat.
Hazardous Decomposition Products: OsO4, Br-
Incompatible Materials: All acids, metal powders, organic solvents.
Hazardous Polymerization: Will not occur
VII SPILL OR LEAK PROCEDURES
Steps to Be Taken in Case Material Is Released or Spilled: Sweep up and place in airtight plastic container.
Waste Disposal Method: Dispose of in accordance with all Local, State, and Federal regulations.
VIII SPECIAL PROTECTION INFORMATION
Respiratory Protection: NIOSH/MSHA approved.
Ventilation: Fume hood
Protective Gloves: Rubber for all contact
Eye Protection: Goggles
Other Protective Equipment: Normal labwear.
IX SPECIAL PRECAUTIONS
Other Precautions: Store in cool dry place, keep tightly sealed when not in use, read MSDS before using.
Precautionary Labeling: In compliance with OSHA and NFPA requirements.
The above information is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. ESPI shall not be held liable for any damage resulting from handling or from contact with the above product.
Issued By: Steve Dierks
Date: November 1994